Chapter 12: Sample Editing: TRIM Mode
Setting the Start / End Points
The start/end points set the part of the sample data which will be played.
The recorded sample may - for example - have silence at the beginning,
which may make it more difficult to place the sound in the correct spot
when hitting the pad. You can fix this by adjusting the start point. You
can also adjust both the start and end points to play only a part of the
phrase. If the sample has extra silence or unwanted sound at the end,
you can delete the empty parts by adjusting the end point and using the
edit feature. This is a good way to free up additional memory.
Start/end points are displayed in sample points. The sample point is the
minimum unit used for sample editing. The MPC5000 has 44,100 sample
points per second.
About the waveform display
The TRIM page displays the waveform of the sample selected in the
'Sample' field. It displays the waveform of the whole sample, with the
parts set by start/end points highlighted.
LEFT / RIGHT / BOTH Waveform View
If you select a stereo sample, you can select the channel (LEFT/RIGHT or
BOTH) to display in the 'View' field.
Adjusting the start point
01. Press [MODE] and [PAD 5] (TRIM).
When you press the [MODE] button, its LED will blink. Pressing [PAD 5] while the [MODE] button’s LED is blinking will display the TRIM page.
02. Select the 'Sample' field and select a sample you wish to edit.
The 'Sample' field is located in the upper left corner of the screen, which displays the sample name. This field chooses which sample's waveform
is to be displayed.
03. Select the 'St' (start) field and adjust the start point.
You can change the start point value by turning the [DATA] wheel. If you press the left or right [CURSOR] buttons while holding [SHIFT], you can
move the cursor to higher points within the numeric display to allow for quicker value selection. You can also enter the value directly with the
numeric keypad.
Additionally, the start point can be edited by moving the [Q1] Q-LINK slider.
04. Hit the pad to check the start point.
When you hit the pad, the MPC5000 plays the sample. The playback method varies depending on the pad.
[PAD 13] (PLAY LOOP)
The MPC5000 will play the sample from the loop point to the end point repeatedly.
[PAD 14] (PLAY TO)
The MPC5000 will play the part before the loop point. If the cursor is on the TRIM END parameter, it will play from the sample start to
the TRIM END. If the cursor is on the LOOP START parameter, it will play from the sample start to the LOOP START. Any other
case, it will play from the sample start to the TRIM START.
[PAD 15] (PLAY FROM)
The MPC5000 will play the sample from the loop point. If the cursor is on the TRIM END parameter, it will play from the TRIM END to
the sample end. If the cursor is on the LOOP START parameter, it will play from the LOOP START to the sample end. Any other
case, it will play from the TRIM START to the sample end.
[PAD 16] (PLAY ALL)
The MPC5000 will play the whole sample.
[PAD 1] to [PAD 12]
The MPC5000 will first play from the start point to the end point, and then play from the loop point to the end point repeatedly.