Akai CT-S21MTD-E3 Manual de Serviço Página 61

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 72
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 60
Issued Date: September 18, 2003
Model No.: V270W - L03
Approval
Note (7) Measurement Setup:
The LCD module should be stabilized at given temperature for 1 hour to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 1 hour in a windless room.
Light Shield Room
(Ambient Luminance < 2 lux)
Display Color Analyzer
(Minolta CA210)
Center of the Screen
LCD Panel
LCD Module
Note (8) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
Horizontal Line
X
3W/4
W/2
W/4
3D/4D/2D/4
43
21
5
: Test Point
X=1 to 5
W
D
Vertical Line
Active Area
20 / 26
The information described in this technical specification is tentative and it is possible to be changed without prior
notice. Please contact CMO ’s representative while your product design is based on this specification. Version 2.0
Vista de página 60